Gold APP Instruments Corporation China Company Logo Gold APP Instruments Corporation China

Pressure Composition Diagram Testing Analyzer H-Sorb 2602

Contact Now* Send an Inquiry to this supplier.
or
Start Order * Name your price

Contact us

Gold APP Instruments Corporation China
[China]

Address
Floor 6th, TianLi Building, No.56 of Zhichun Road, HaiDian District Beijing Beijing
Phone
86-182-01085158
Contact name
Andy

Quick Information

  • Brand Name: Gold APP Instruments
  • Place of Origin: China
  • Model Number : H-Sorb 2602
  • :

Description

H-Sorb 2602 high pressure gas adsorption volumetric principle analyzer introduction


Gas sorption analysis is important in many fields of materials, such as energy storage materials, improved catalysts for petrochemical processing, advanced pharmaceuticals and food industries. At present, there is tremendous interest in the development of innovative materials for the transition to renewable energy. The science of gas sorption has become particularly critical in the advancement of materials for storing fuel gases such as hydrogen or natural gas, as well as for sequestration of greenhouse gases.
 
The H-Sorb 2602 high pressure gas sorption analyzer adopts the volumetric technique principle which consists of dosing a known amount of gas adsorptive into measurement tubes where lying samples (such as zeolites, carbon nanotubes, rocks, catalysts, activated carbons, molecular sieve, hydrides etc. ) to be analyzed. When samples reach equilibrium with the adsorbate gas (such as hydrogen, methane, carbon dioxide, nitrogen, argon, krypton etc.), detailed and comprehensive final equilibrium pressures will be recorded automated by Gold APP Instruments company dedicated and patented software. These data are used to calculate the quantity of gas adsorbed by samples. This measurement procedure automatically repeated by software under given temperature and pressure intervals until finalized the maximum preselected pressure. Finally, each of the equilibrium points’ volume adsorbed, equilibrium pressure, absolute pressure etc. data are plotted to produce the isotherm. By using the isotherm data, operators can calculate further more information such as Langmuir fitting isotherm, the adsorption rate curve, PCT (pressure-composition-temperature) or PCI (pressure-composition-isotherm) curve etc.
 
Pressure-Composition Isotherms (PCI) and Pressure-Composition Temperature (PCT) is one of the most informative sorption measurements. The result is a plot of the equilibrium absorbed gas concentration in the material as a function of pressure and temperature.
 
Gold APP Instruments high pressure and high temperature gas sorption analyzer H-Sorb 2602 adopts static volumetric principle to determine adsorption and desorption isotherms under high pressure (atmospheric to 200Bar) and high temperature (atmospheric to 500℃) with a stainless steel VCR manifolds system, fully automated operation can control system and multi calculation methods, all these guarantee H-Sorb 2602 to produce a highly repeatibility and highly precision analysis data.
 


 H-Sorb 2602 high pressure gas adsorption volumetric principle analyzer application
 
 
  1. Study and research in high temperature and pressure gas sorption, supercritical gas performance, microporous materials, hydrogen storage materials, coalbed gas, oil exploration, methane etc.
  2. Catalysts, molecular sieves, active carbon, carbon nano-tube, fuel cell, hydrocarbon and other materials.

 
 
H-Sorb 2602 high pressure gas adsorption volumetric principle analyzer parameters
 
 
  • Analysis Method: static volumetric principle, high pressure gas sorption principle
  • Versatility: adsorption/desorption isotherms measurement (atmospheric to 500℃), Gibbs supercritical adsorption measurement
  • Data Reduction: Langmuir model regression isotherm, PCT(Pressure-Composition-Temperature) or PCI (Pressure-Composition-Isotherm) diagram/curve/isotherm measurement, Langmuir maximum adsorption constant L and adsorption pressure constant B measurement; Langmuir correction model loading-ratio correlation regression (LCR) isotherm; Ono-Kondo (OK) lattice model isotherm regression; adsorptive gas density and vapor-liquid equilibrium accuracy calculation under different pressures and temperatures
  • Measuring Ranges: continuous adsorption and desorption measurement from atmospheric to 200Bar pressure
  • Accuracy: repeatability errors <3%
  • Temperature Range: cryogenic to 500℃, accuracy±0.1℃
  • Sample Ports: two samples analyzing and two degassing, stainless-steel micro welding sample cells, software integrated temperature PID adjustment
  • Transducer Accuracy: imported high precision transmitter, accuracy can reach 0.05% of F.S. (full-scale), long-duration usage stability is 0.025% of F.S.
  • Ultimate Vacuum: 4x10-2 Pa (3x10-4 Torr), molecular pump system (1x10-6 Pa) is optional
  • Adsorbate Gas: high purity nitrogen, CO2 or others (Ar, Kr, H2, CH4 etc.)
  • Data Acquisition: high-precision and high integration data acquisition modules, minimal error, strong anti-interference ability
  • Specifications: Height 22.05 inches (56cm)* Width 20.87 inches (53cm)*Depth 23.62 inches (60cm); 132 pound (60kg); 220V/5A
 



 
H-Sorb 2602 high pressure gas adsorption volumetric principle analyzer features:
 
 
  1. Control System: imported VCR interface high pressure pneumatic valve can realize auto on-off within 200Bar, sealing performance is top to 1x10-10 Pa.m3/s, can be used more than 500 million times; programmable logic controller (PLC) system, high integration and sound anti-interference, improve stability and prolong life
 
 
  1. Analysis Management: parameters be set by Gold APP Instruments software, fully automated, achieved unattended operation at night; H-Sorb mode is available for accurate control gas charging pressure points, gain ideal data points
  2. Manifold System: imported 316L stainless steel thick-walled manifolds, micro welding sealing can reduce dead space largely; metal VCR connection is convenient for installation and uninstallation
 
 
  1. Safety Measures: H-Sorb asymptotic technology realizes auto gas-charging and degassing, prevents high pressure dangers caused by artificial misoperation, and also minimizes large differential pressure’s impact to pressure transducer
 



 
Our policy of continuous development may cause the information and specifications contained herein to change without notice or liability.
 



find more details from www.goldapp.com.cn, thanks.



Price

  • Delivery Port : Beijing

Packaging & Delivery

  • Packing :Plywood Box
  • Packaging Size : 70 x 70 x 85  Centimeters
  • Package Weight : 80  Kilograms
  • Delivery Lead Time : 30 working days
  • Supply Ability : 20 sets per month

Product Image

  • Pressure Composition Diagram Testing Analyzer H-Sorb 2602 image

Send an Inquiry to this supplier

Send an Inquiry to this supplier
* From
  To Andy
Gold APP Instruments Corporation China
* Buying Product
- Please enter your specific buying item.
e.g. 42 inch LCD TV, leather executive chair
Category : Other Paint & Coatings
* Message

Use English only Max. 2000 characters. (Min. 20)

Send
EC21.com does not guarantee the validity of product information or the credentials of sellers.

Browse: Manufacturer Directory Premium Suppliers Site Map

About EC21 Contact Us Terms & Conditions Report Item Online Trading Risks Product Listing Policy

Copyright (c)1997-2026 EC21 Inc. All Rights Reserved. EC21 in KoreanChinese

Business Registry Number: 120-86-03931 | Mall order sales Registration Number: 강남-5838